|本期目录/Table of Contents|

[1]庄孙歧,程建杰,何嘉鹏,等.相变蓄能砌体外墙中间歇通风的热过程分析[J].南京工业大学学报(自然科学版),2015,37(01):111-116.[doi:10.3969/j.issn.1671-7627.2015.01.020]
 ZHUANG Sunqi,CHENG Jianjie,HE Jiapeng,et al.Heat process analysis on intermittent ventilation on phase change energy storage wall[J].Journal of NANJING TECH UNIVERSITY(NATURAL SCIENCE EDITION),2015,37(01):111-116.[doi:10.3969/j.issn.1671-7627.2015.01.020]
点击复制

相变蓄能砌体外墙中间歇通风的热过程分析()
分享到:

《南京工业大学学报(自然科学版)》[ISSN:1671-7627/CN:32-1670/N]

卷:
37
期数:
2015年01期
页码:
111-116
栏目:
出版日期:
2015-01-19

文章信息/Info

Title:
Heat process analysis on intermittent ventilation on phase change energy storage wall
文章编号:
1671-7627(2015)01-0111-06
作者:
庄孙歧1程建杰1何嘉鹏1张源2
1.南京工业大学 城市建设与安全工程学院,江苏 南京 210009; 2.东南大学 能源与环境学院,江苏 南京 210096
Author(s):
ZHUANG Sunqi1CHENG Jianjie1HE Jiapeng1ZHANG Yuan2
1.College of Urban Construction & Safety Engineering,Nanjing Tech University,Nanjing 210009,China; 2.School of Energy and Environment,Southeast University,Nanjing 210096,China
关键词:
相变蓄热 间歇通风 室内温度 热流
Keywords:
phase change thermal storage intermittent ventilation indoor temperature flux
分类号:
TU111.4+8
DOI:
10.3969/j.issn.1671-7627.2015.01.020
文献标志码:
A
摘要:
基于焓法模型,利用Fluent软件模拟分析南京地区民用建筑南外墙在夏季典型气候与太阳辐射共同作用下,绝热材料发泡聚苯乙烯(EPS)与相变材料(PCM)在三排孔砌块中不同组合时,间歇通风风速变化对室内的热影响。结果表明:相变墙外孔中为保温材料、内孔中为相变材料(构造B)在流速为2 m/s时效果最佳,在此流速下稳定后的一个周期内,室内温度波动值与热流密度相对于无机械通风分别降低了67.5%和74.04%,且温度波动平均值等于相变温度31.1 ℃,这样能充分发挥相变材料的作用。
Abstract:
With the combined effects on a typical summer climate and solar radiation,the south wall of civil architecture in Nanjing summer was investigated.Based on enthalpy model,Fluent software was used to simulate and analyze the indoor heat influence on the velocity of intermittent ventilation when the thermal insulation material expanded polystyrene(EPS)and phase change materials(PCM)for different combinations of the three-hole block.Results showed that the phase change wall with EPS in outer hole and PCM in inner hole(structure B)worked best at the velocity of 2 m/s.Compared with no mechanical ventilation,the reduction of temperature swing value and flux was 67.5% and 74.04%,respectively,in a stable cycle at the velocity,and the indoor temperature swing average value was equal to the phase change temperature of 31.1 ℃ with the full function of PCM.

参考文献/References:

[1] 李永财.太阳能通风技术结合相变蓄热材料自然通风效果实验研究[D].重庆:重庆大学,2009.
[[2] 王源霞.太阳能通风结合相变墙体在夏热冬暖地区的应用研究[D].广州:华南理工大学,2012.
[[3] Medved S,Arkar C.Correlation between the local climate and the free-cooling potential of latent heat storage[J].Energy and Buildings,2008,40:429-437.
[[4] Álvarez S,Cabeza F L,Ruiz-Pardo A,et al.Building integration of PCM for natural cooling of buildings[J].Applied Energy,2013,109:514-522.
[[5] Graciad A,Navarro L,Castell A,et al.Experimental study of a ventilated facade with PCM during winter period[J].Energy and Buildings,2013,58:324-332.
[[6] Darzi R A A,Moosania S M,Tan F L,et al.Numerical investigation of free-cooling system using plate type PCM storage[J].International Communications in Heat and Mass Transfer,2013,48:155-163.
[[7] 中华人民共和国住房和城乡建设部.GB 50736—2012民用建筑供暖通风与空气调节设计规范[S].北京:中国建筑工业出版社,2012.
[[8] 赵荣义,范存养,薛殿华,等.空气调节[M].4版.北京:中国建筑工业出版社,2008:29-33.
[[9] 陈林辉,田怀璋,梁俊杰,等.固液相变蓄能三种数学模型研究比较[C]//第六届全国低温与制冷工程大会会议论文集.西安:中国制冷学会,2003.
[[10] 曾艳,田怀璋,余鹏.固液相变蓄能的数学模型和自然对流换热系数的实验研究[J].制冷与空调,2002,2(2):15-18.
[[11] 肖伟,王馨,张寅平.定形相变墙板改善轻质墙体夏季隔热性能研究[J].工程热物理学报,2009,30(9):1561-1563.
[[12] 李丽莎,闫全英.相变围护结构的研究及发展[J].材料导报,2010,24(16):304-312.
[[13] 林坤平,张寅平,江亿.我国不同气候地区夏季相变墙房间热性能模拟和评价[J].太阳能学报,2003,24(1):46-52.

备注/Memo

备注/Memo:
收稿日期:2014-02-21
基金项目:“十二五”国家科技支撑计划(2011BAE14B06)
作者简介:庄孙歧(1989—),男,江苏常州人,硕士,主要研究方向为相变传热和建筑节能; 程建杰(联系人),副教授,E-mail:chengjianjienn@126.com.
引用本文:庄孙歧,程建杰,何嘉鹏,等.相变蓄能砌体外墙中间歇通风的热过程分析[J].南京工业大学学报:自然科学版,2015,37(1):111-116..